TY - JOUR KW - Data accuracy KW - diagnosis KW - Mycobacterium leprae KW - Systematic review AU - Torres R AU - Fachi M AU - Böger B AU - Marson B AU - Ferreira V AU - Pontarolo R AU - Guimarães T AB -

This systematic review (number register: CRD42018112736) was performed to compare the sensitivity and specificity of leprosy diagnostic methods. The search was conducted in 3 electronic databases in January 2021. Studies evaluating leprosy diagnostic tests were included according the eligibility criteria. Meta-analysis was performed to calculate the sensibility and specificity of the groups. We included 36 studies. The test sensitivity for paucibacillary patients was 0.31 (95%CI: 0.29-0.33) and the specificity was 0.92 (95%CI: 0.92-0.93). In multibacillary patients, the sensitivity was 0.78 (95%CI: 0.77-0.80) and specificity was 0.92 (95%CI: 0.92-0.93). Comparing the sensitivity and specificity of the different techniques included, it should be noted that polymerase chain reaction (PCR) test presented the highest sensitivity for paucibacillary patients, while the western blot technique showed the highest sensitivity for multibacillary patients. However, further studies are needed to optimise the diagnosis of leprosy, requiring research with a larger number of samples and more uniform protocols.

BT - Diagnostic microbiology and infectious disease C1 - https://www.ncbi.nlm.nih.gov/pubmed/33610964 DA - 02/2021 DO - 10.1016/j.diagmicrobio.2021.115337 IS - 2 J2 - Diagn Microbiol Infect Dis LA - eng N2 -

This systematic review (number register: CRD42018112736) was performed to compare the sensitivity and specificity of leprosy diagnostic methods. The search was conducted in 3 electronic databases in January 2021. Studies evaluating leprosy diagnostic tests were included according the eligibility criteria. Meta-analysis was performed to calculate the sensibility and specificity of the groups. We included 36 studies. The test sensitivity for paucibacillary patients was 0.31 (95%CI: 0.29-0.33) and the specificity was 0.92 (95%CI: 0.92-0.93). In multibacillary patients, the sensitivity was 0.78 (95%CI: 0.77-0.80) and specificity was 0.92 (95%CI: 0.92-0.93). Comparing the sensitivity and specificity of the different techniques included, it should be noted that polymerase chain reaction (PCR) test presented the highest sensitivity for paucibacillary patients, while the western blot technique showed the highest sensitivity for multibacillary patients. However, further studies are needed to optimise the diagnosis of leprosy, requiring research with a larger number of samples and more uniform protocols.

PY - 2021 EP - 115337 T2 - Diagnostic microbiology and infectious disease TI - Sensitivity and specificity of multibacillary and paucibacillary leprosy laboratory tests: A systematic review and meta-analysis. VL - 100 SN - 1879-0070 ER -